Caterpillar Excavator Governor Motor Performance Parameters and Introduction

As one of our hot sale products,  Caterpillar Excavator governor motor is guaranteed by its high quality. All the components on the drive module are authentic and imported from Japan, just the same as the original board. This ensures its complete compatibility with the host and stability. The locator is high-precision imported locator with an accuracy of 1%. The small motor is the original production imported from Japan with high speed, low noise, large torque and long life advantages.

In the fueling and refueling process, pull the throttle line, within 1.2 seconds to 2.0 seconds in the drive board, the motor current increases to 2.12A, drive board CPU will start the output protection, and the motor stops. The throttle motor is under protection during the whole protection process, including flameout and the acceleration and deceleration process. 6.Aging and tensile testing: a simulation of the original machine work using overloaded items over 10kg. The test has been pulling up and down for 24 hours and the test result is normal.

On-machine test: clear file, strong driving force, throttle stuck and short circuit can be protected, high resistance to high temperature, accurate through the computer calibration. All functional tests meet the original requirements.

                                                                                                   Performance parameters

Voltage(V) No-load current(A) Load tension(N) Load current(A)
                         24                         0.45                       160                1.68
Pull-line travel(MM) Sensor voltage(V) Sensor resistance
precision(KΩ±10%)
Humidity(RH)
                         60                          5                         1%                <98%
Operating temperature(°) Storage temperature(°)
                      -20~75                     -30~80

Caterpillar governor motorCaterpillar governor motor

In the fueling and refueling process, pull the throttle line, within 1.2 seconds to 2.0 seconds in the drive board, the motor current increases to 2.12A, drive board CPU will start the output protection, and the motor stops. The throttle motor is under protection during the whole protection process, including flameout and the acceleration and deceleration process. 6.Aging and tensile testing: a simulation of the original machine work using overloaded items over 10kg. The test has been pulling up and down for 24 hours and the test result is normal.